Key Highlights of 6.2KW EU Standard Hybrid Inverter
1 High efficiency hybrid solar charge inverter for home and commercial use supports on grid and off grid applications with seamless power supply. It handles continuous impact loads delivers stable pure sine wave output and protects sensitive electronics. It supports up to 6 units in parallel for scalable power expansion and three phase system building meeting diverse power needs. It features UPS level fast switching ensuring no power interruption during grid outages.
2 Advanced PV and battery compatibility make this inverter highly versatile. It supports 27A PV input compatible with all residential solar modules and flexible arrays the MPPT controller maximizes energy harvesting. It works with lead acid and lithium batteries with adjustable charging current for optimal battery care. It supports diesel generator input and can operate without batteries with PV and grid powering loads together. Zero export to grid and remote diagnostics enhance system control and maintenance convenience.
3 Robust safety features ensure long term reliability. It comes with overload overvoltage short circuit and over temperature protection to safeguard the inverter and connected devices. Circuit breaker and blown fuse protection add extra safety against electrical faults. With wide operating temperature range it performs reliably in various environments. The variable speed fan cooling system ensures efficient heat dissipation for stable performance under heavy loads.
4 Smart and user friendly design simplifies operation and monitoring. The intuitive LCD display provides clear real time data on system status power output and battery levels. Multiple communication interfaces enable remote monitoring and control. The unit supports OTA updates for easy firmware upgrades. Its compact size and lightweight design make installation and maintenance straightforward saving time and effort.
(102% < load <125%) ±10%: report error and turn off the output after 5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds;
Peak power
24000VA
Loaded motor capability
8HP
Output short circuit protection
200ms Protection
Bypass circuit breaker specification
63A
AC charging
Rated battery input voltage
51.2V (Minimum starting voltage 44V)
Battery voltage range
40.0Vdc~60Vdc±0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery… settable on LCD screen)