Key Highlights of 6.5KW US Standard Hybrid Inverter
1 Our 48V Split Phase Hybrid Solar Inverter is engineered for North American residential and commercial energy storage systems. This US-standard 3.6KW/6.5KW inverter delivers >95% maximum efficiency with CT zero export to grid capability. It provides 125% EPS peak output for 5 seconds to handle load surges, with UPS-level 10ms switching time for uninterrupted power. Up to 6 units can be paralleled for system expansion, while remote diagnostics and OTA updates ensure optimal performance. The intuitive LCD interface enables real-time monitoring and easy operation for professional installers and end users.
2 This hybrid inverter features 48V nominal battery input (44V min start) with 40-60.6Vdc operating range and intelligent voltage protection. Pure sine wave output delivers 3600VA/3600W at 120Vac with 50/60Hz auto detection. Advanced MPPT operates at 90-260Vdc, handling 4000W/22A max PV input with 80-300Vdc operating range. Configurable charging current reaches 80A with 40A max bypass overload capacity. Compact dimensions: 415x280x100mm, weight: 7.8kg for space-saving installation.
3 This inverter enables complete energy independence for residential applications, significantly reducing electricity costs through optimized self-consumption. It allows selling excess solar energy to grid while providing reliable backup power during outages. Suitable for both on-grid and off-grid operation, it works perfectly for remote locations, vacation homes and tiny houses. Commercial users benefit from scalable architecture and regulatory compliance with zero export functionality for grid-tied installations.
4 Certified to CE (IEC62109-1;2) and EN61000 C2 EMC standards, this inverter operates reliably from -15°C to 55°C with 5-95% humidity tolerance. Forced air cooling maintains optimal temperatures for extended lifespan. We provide free replacement parts and comprehensive online technical support.
(102% < load <110%) 10%: report error and turn off the output after 5 minutes;(110% < load < 125%) 10%: report error and turn off the output after 10 seconds;Load >125% +10%: report error and turn off the output after 5 seconds;
Peak power
12000VA
Loaded motor capability
5HP
Output short circuit protection
Circuit breaker
Bypass circuit breaker phase specification
63A
Rated battery input voltage
1
Battery voltage range
40.0Vdc~60Vdc+0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltagealarm /overvoltage recovery… settable on LCD screen)